Files
OpenFlare/internal/apps/config/system_config_cache_test.go
T
ryan d3ba767087 perf(config): add Otter RAM cache layer for system configs
Introduce pkg/cache/ram on top of existing Redis/DB config reads.
GetByKey now checks local RAM before Redis. Unified invalidation clears
RAM and Redis hash fields on admin writes, with pub/sub for multi-node
RAM eviction. Add tests and wire create/update/migrator write paths.
2026-06-17 11:57:04 +08:00

106 lines
3.4 KiB
Go

// Copyright 2026 Arctel.net
// SPDX-License-Identifier: Apache-2.0
package config
import (
"context"
"errors"
"testing"
"github.com/redis/go-redis/v9"
"github.com/Rain-kl/Wavelet/internal/db"
"github.com/Rain-kl/Wavelet/internal/model"
"github.com/Rain-kl/Wavelet/internal/testhelper"
)
func TestSystemConfigRAMCacheServesUntilInvalidated(t *testing.T) {
dbConn, _, cleanup := testhelper.SetupTestEnvironment(t)
defer cleanup()
ctx := context.Background()
model.ResetSystemConfigRAMCacheForTest()
if err := model.InvalidateAllSystemConfigCaches(ctx); err != nil {
t.Fatalf("InvalidateAllSystemConfigCaches() error = %v", err)
}
var warm model.SystemConfig
if err := warm.GetByKey(ctx, model.ConfigKeySiteName); err != nil {
t.Fatalf("GetByKey(site_name) warm error = %v", err)
}
if warm.Value != "Wavelet" {
t.Fatalf("GetByKey(site_name).Value = %q, want %q", warm.Value, "Wavelet")
}
if err := dbConn.Model(&model.SystemConfig{}).
Where("key = ?", model.ConfigKeySiteName).
Update("value", "ram_probe_value").Error; err != nil {
t.Fatalf("Update(site_name) error = %v", err)
}
if err := db.HDel(ctx, model.SystemConfigRedisHashKey, model.ConfigKeySiteName); err != nil {
t.Fatalf("HDel(site_name) error = %v", err)
}
var cached model.SystemConfig
if err := cached.GetByKey(ctx, model.ConfigKeySiteName); err != nil {
t.Fatalf("GetByKey(site_name) cached error = %v", err)
}
if cached.Value != "Wavelet" {
t.Fatalf("GetByKey(site_name).Value = %q, want stale RAM value %q", cached.Value, "Wavelet")
}
if err := model.InvalidateSystemConfigCache(ctx, model.ConfigKeySiteName); err != nil {
t.Fatalf("InvalidateSystemConfigCache(site_name) error = %v", err)
}
var refreshed model.SystemConfig
if err := refreshed.GetByKey(ctx, model.ConfigKeySiteName); err != nil {
t.Fatalf("GetByKey(site_name) refreshed error = %v", err)
}
if refreshed.Value != "ram_probe_value" {
t.Fatalf("GetByKey(site_name).Value = %q, want %q", refreshed.Value, "ram_probe_value")
}
exists, err := db.Redis.HExists(ctx, db.PrefixedKey(model.SystemConfigRedisHashKey), model.ConfigKeySiteName).Result()
if err != nil {
t.Fatalf("HExists(site_name) error = %v", err)
}
if !exists {
t.Fatal("expected redis hash field to be repopulated after refresh")
}
}
func TestInvalidateSystemConfigCacheClearsRedisField(t *testing.T) {
dbConn, _, cleanup := testhelper.SetupTestEnvironment(t)
defer cleanup()
ctx := context.Background()
var sc model.SystemConfig
if err := sc.GetByKey(ctx, model.ConfigKeySiteName); err != nil {
t.Fatalf("GetByKey(site_name) error = %v", err)
}
if err := model.InvalidateSystemConfigCache(ctx, model.ConfigKeySiteName); err != nil {
t.Fatalf("InvalidateSystemConfigCache(site_name) error = %v", err)
}
_, err := db.Redis.HGet(ctx, db.PrefixedKey(model.SystemConfigRedisHashKey), model.ConfigKeySiteName).Result()
if !errors.Is(err, redis.Nil) {
t.Fatalf("HGet(site_name) error = %v, want redis.Nil", err)
}
if err := dbConn.Model(&model.SystemConfig{}).
Where("key = ?", model.ConfigKeySiteName).
Update("value", "after_invalidate").Error; err != nil {
t.Fatalf("Update(site_name) error = %v", err)
}
var refreshed model.SystemConfig
if err := refreshed.GetByKey(ctx, model.ConfigKeySiteName); err != nil {
t.Fatalf("GetByKey(site_name) refreshed error = %v", err)
}
if refreshed.Value != "after_invalidate" {
t.Fatalf("GetByKey(site_name).Value = %q, want %q", refreshed.Value, "after_invalidate")
}
}